INVESTIGATION OF USING PHASE CHANGE MATERIALS (PCMS) IN RESIDENTIAL BUILDINGS FOR IMPROVING COOLING SYSTEM IN HOT AND DRY CLIMATE

  • Bashir Eskander Kareem
  • [email protected]
  • 0750 113 4682
  • P.hD. [Bashir Eskander Kareem]
  • Global energy consumption has risen over the past decade, driven by the growth in population and the economy. The building sector is the largest energy consumer, accounting for 40% of total energy and causing one-third of CO2 emissions. Half of building energy consumption goes to HVAC systems. Thermal energy storage offers an excellent method for providing sustainable energy that can be utilized for free cooling, heating, and ventilation in buildings.

    The free cooling system stores thermal energy in thermal energy storage during the night and utilizes it throughout the day. Latent heat thermal energy storage is recommended due to its high energy capacity, minimal impact on temperature and volume changes. The primary challenges associated with integrating PCM in free cooling systems pertain to the thermophysical properties of PCM itself and the system's reliance on climatic conditions.

    In hot climates, solidifying PCM may encounter challenges. As a potential solution, there is a proposal to incorporate an evaporative cooling system with a PCM-to-air heat exchanger, with the goal of facilitating the PCM solidification process.

    In this study, the enthalpy method has been employed in the CFD model for the PCM-to-air heat exchanger, and the EES model has been utilized for the entire system. The system consists of a multi-stage evaporative cooler and a PCM-to-air heat exchanger. According to the CFD findings, the melting and solidification time is reduced with decreasing PCM panel thickness, decreasing air channel height, increasing PCM panel length, and higher flow rate of HTF. The main parameter to change melting and solidification time is the temperature difference between HTF and PCM’s melting temperature.

    The primary objective of this study is to design, construct, and develop a cooling and ventilation system that incorporates both evaporative cooling and a PCM-to-air heat exchanger.

    The system employs organic paraffin-based PCMs-RT21HC and RT25HC, arranged in series to reduce melting and solidification durations. Experimental and numerical findings demonstrate that starting with PCM RT21HC in the heat exchanger reduces solidification time, while initiating with PCM RT25HC shortens the melting time. Also, the results clearly demonstrate that the solidification time is significantly longer compared to the melting time. PCMs completely melt in less than 4 hours, whereas PCM-RT21HC does not solidify completely even after 12 hours.

    Utilizing PAHX without a cooling system can provide thermal comfort for less than 4 hours, but when combined with evaporative cooling, the PCMs can solidify, enabling the system to operate continuously and effectively.

    The system offers cooling and ventilation, effectively extending indoor thermal comfort by stabilizing the outlet air temperature through the use of PCM to air heat exchanger. Typically, the supply air temperature to the conditioned space ranges between 21 to 25°C.

  • Erbil Technical Engineering College
  • Mechanical and Energy Engineering
  • Thermo-fluid

PERFORMANCE ENHANCEMENT OF PHOTOVOLTAIC PANEL USING SINGLE AXIS TRACKING AND WATER SPRAY SYSTEMS

  • Sally Afram Polus
  • [email protected]
  • 0750 766 6511
  • Ph.D._Sally Afram Polus
  • A solar tracking system with an effective cooling technique is developed
    and implemented in this study, because the solar irradiance, temperature and
    dusty climate condition affected on the output of photovoltaic panel. A single
    east-west solar tracking system incorporating a monocrystalline panel and a
    front surface spray water cooling system was conducted and compared to a
    fixed reference panel with an inclination angle 36° facing south. An appropriate
    cooling system was developed with six nozzles placed on top, left and right
    side of the panel, to ensure that the panel’s front surface is covered with water
    from all orientations. Two different types of spray water cooling were
    performed; first by adjusting the panel surface temperature (35 °C, 40 °C and
    45 °C), through adjustable water flow rate, and the second was fixing the water
    volume flow rate at (2 l/min, 3 l/min, 4 l/min and 5 l/min). This experiment was
    conducted during the summer season of the year 2022 in Erbil, Iraq (latitude
    36.191° and longitude 44.009°).
    A simulation study was also conducted using ANSYS Fluent R19.2. The
    experimental study demonstrated a maximum electrical efficiency
    improvement reaching 9.9% which was recorded as an enhancement compared
    to the fixed reference panel by using the solar east-west tracking system. While
    tracking with a cooling system at 35 °C set point temperature has resulted in an
    improvement in efficiency up to 25.11%. Another parameter that has been
    optimized is the cooling water consumption. The optimal cooling setting
    temperature was determined at a surface temperature of 40 °C. Alternatively,
    upon the incorporation of a cooling system to the PV panel at setpoint
    temperatures of 45 °C, 40 °C, and 35 °C, without the integration of a solar
    tracking system, improvements of 18.25%, 19.94%, and 22.82% were achieved
    in electrical efficiency, respectively. When the solar radiation exceeds the
    power at standard operating conditions, even if the panel temperature is higher
    VIII
    than that of the standard test, the PV panel is able to produce the same power
    as the standard test of 210 W. Additionally, integrating a solar tracking system
    with cooling at a water volume flow rate of 2 L/min resulted in double the
    power production compared to a fixed panel cooled at the same flow rate. This
    model demonstrates that the performance of a photovoltaic panel decreased by
    only 0.2-0.3% when the surface temperature increased by 5 °C within a range
    of 25 to 40 °C.
    The simulation results indicated that the impact of the different variables
    on both panel performance as well as temperature could be accurately predicted
    and the temperature of the photovoltaic panel reduced significantly, leading to
    an increase in power production. The contribution from the ANSYS fluent
    simulation was that solar radiation intensity is the most influential factor on
    cooled PV module power production, as by maximizing solar irradiance by 100
    W/m2
    , the power production will be increased by 16.6%. While increasing the
    water flow rate at a lower water inlet temperature improved the performance of
    the photovoltaic panel. This study provides insights essential for design and
    implementation of efficient photovoltaic with front surface cooling.

  • Erbil Technical Engineering College
  • mechanical and energy engineering department
  • thermo fluid

التكامل بين تقنيتي محاسبة تكاليف تدفق المواد (MFCA) وسلسلة التجهيز (Supply Chain) لتحقيق الميزة التنافسية في الشركات الصناعية دراسة تطبيقية لعينة من الشركات الصناعية في محافظة أربيل

  • Ahmed Burhan Mousa
  • [email protected]
  • 0750 426 0803
  • الاطرحة احمد برهان (MFCA & Supply chain)
  • المستخلص

    تهدف هذه الدراسة بشكل رئيس الى بيان مدى إمكانية تحقيق التكامل بين تقنيتي محاسبة تكاليف تدفق المواد وسلسلة التجهيز في دعم الميزة التنافسية، من خلال تخفيض التكلفة وتقليل الوقت والتي تعتبر من العوامل الحاسمة لمواجهة المنافسة والبقاء والاستمرار والنجاح والتفوق لكثير من الشركات الصناعية في الأسواق المتغيرة في الوقت الحالي.

    ولقد استخدم الباحث المنهج العملي، لتحقيق أهداف الدراسة واختبار فرضياتها من خلال تطبيق تقنية محاسبة تكاليف تدفق المواد وتصميم أنشطة سلسلة التجهيز على البيانات الفعلية لشركتي "رسن ستيل" لتصنيع الهياكل الحديدية، و"ريل بنل" لإنتاج طبقات ساندويج بنل، وهو الجانب التطبيقي الخاص بالدراسة.

    ومن أهم نتائج الدراسة التي توصل اليها الباحث: هي أن هنالك علاقة مترابطة وتكامل بين تطبيق تقنية محاسبة تكاليف تدفق المواد ضمن سلسلة التجهيز مع أبعاد الميزة التنافسية من التكلفة والوقت.

    وقد خلصت الدراسة الى توصيات عديدة أهمها، أن تتبنى الشركات الصناعية المحلية بضمنها شركتي عينة الدراسة الإطار المقترح للتكامل بين تقنيتي محاسبة تكاليف تدفق المواد ومدخل سلسلة التجهيز من أجل تعزيز قوتها ومعالجة ضعفها، وذلك لتحقيق الميزة التنافسية في ظل بيئة التصنيع الحديثة.

  • Erbil Technical Administrative College
  • Accounting
  • Cost and Managerial Accounting

دور التبني الالزامي لمعايير الابلاغ المالي الدولية في عملية تدقيق الحسابات وانعكاسه في ممارسات التدقيق غير المنتظم

  • salwan neamat hanna
  • [email protected]
  • 0750 424 5122
  • اطروحة دكتوراه د. سلوان نعمت حنا
  • المستخلص

    تهدف الدراسة الى تحديد دور التبني الالزامي لمعايير (IFRSs-IASs) في عملية تدقيق الحسابات وانعكاسه في ممارسات التدقيق غير المنتظم، نتيجة قيام مراقبـي الحسابات العاملين في إقليم كوردستان / العراق بتبني ممارسات التدقيق غير المنتظم استجابةً للضغوط التي يتعرضون لها عند التعامل مع وتطبيق تلك المعايير، فضلاً عن الضغوط التي قد تفرضها على عملية تدقيق الحسابات بشكل عام من جانب تعقيد مهمة التدقيق، واتساع نطاق عملية التدقيق، وضغوط وقت عملية التدقيق، واتعاب التدقيق التي قد تؤدي بمراقبـي الحسابات الى الانخراط في ممارسات التدقيق غير المنتظم.

    وتمت تغطية الدراسة من خلال الاطار الميداني، اذ تم استقصاء آراء الاكاديميين المختصين ومراقبـي الحسابات في اقليم كوردستان / العراق حول موضوع الدراسة، وتم اختيار مجموعة من الاكاديميين المختصين (الاساتذة الجامعيين)، ومراقبـي الحسابات كعينة للدراسة والذين بلغ عددهم (168) فرداً، وتم توزيع استمارات الاستبانة عليهم، ومن ثم تم تحليل النتائج باستخدام برنامج الحزمة الاحصائية للعلوم الاجتماعية (SPSS).

    وتوصلت الدراسة الى مجموعة من الاستنتاجات أهمها، ان معايير (IFRSs-IASs) تتميز بطبيعتها المعقدة التي تتطلب وجود إمكانيات وقدرات عالية لتفسيرها وتطبيقها، كما وان الزام الوحدات الاقتصادية في الإقليم بتبنيها يخلق ضغوطاً على عملية تدقيق الحسابات، ويجعل مراقبـي الحسابات ان ينخرطوا بممارسات التدقيق غير المنتظم، التي تؤثر بشكل سلبي في جودة الأداء المهني، وجودة العملية التدقيقية، وسمعة مهنة تدقيق الحسابات في الاقليم.

    وعليه أوصى الباحث دراسة وتحليل تجارب الدول المتقدمة التي اتخذت خطوات جادة ونجحت في التحول الى تطبيق معايير (IFRSs-IASs) بشكل سليم، الى جانب قيام المنظمات المهنية في الاقليم بإعادة تهيئة البيئة المحاسبية والتدقيقية لتتوافق مع استخدام أساس المبادئ في صياغة المعايير، سواء أكانت من حيث الثقافة المحاسبية، التعليم المحاسبي، توجيه مراقبـي الحسابات، البيئة الرقابية، ممارسة الاحكام المهنية، وغيرها من العوامل الحاكمة لتطبيق هذا النوع من المعايير، فضلاً عن تعزيز سمعة مهنة تدقيق الحسابات في الاقليم من خلال فرض عقوبات وغرامات على مراقبـي الحسابات الذين يثبت بانهم يمارسون سلوكيات مختلة وممارسات غير منتظمة، ولا يلتزمون بأخلاقيات المهنة، ويخرجون عن السلوك والأداء المهني السليم عند أداء مهام التدقيق.

  • Erbil Technical Administrative College
  • Accounting Techniques
  • Financial Accounting